MantisBT - Zandronum
View Issue Details
0000471Zandronum[All Projects] Bugpublic2011-05-27 01:522018-09-30 19:57
M0rbid Desire 
Torr Samaho 
normaltweakalways
closedfixed 
MicrosoftWindows 764-Bit
 
1.0 
0000471: Swimmable below fake floor only. Why ceiling too?
Anooother issue when I was mapping.

Normally I use "Draw fake Floor only" for deep waters.

But, when I set "Draw Fake Floor only" + "Swimmable below fake" it assigns deep water in the fake floor AND in the "ceiling" too.

This issue is not present in ZDoom SVN.
1-Download the example WAD.

2-Run with both source ports. (Skulltag 98X - ZDoom SVN versions)
PD: I'll consider the tiny issues as bug, not as suggestion.
No tags attached.
? prueba_transf_height_swimmable.wad (3,736) 2011-05-27 01:52
/tracker/file_download.php?file_id=346&type=bug
Issue History
2011-05-27 01:52M0rbid DesireNew Issue
2011-05-27 01:52M0rbid DesireFile Added: prueba_transf_height_swimmable.wad
2011-05-27 04:06unknownnaNote Added: 0001766
2011-05-27 04:06unknownnaNote Edited: 0001766bug_revision_view_page.php?bugnote_id=1766#r910
2011-05-27 04:10unknownnaStatusnew => confirmed
2011-06-13 15:27Torr SamahoNote Added: 0001792
2011-08-26 21:26M0rbid DesireNote Added: 0002142
2012-01-15 14:55Torr SamahoStatusconfirmed => resolved
2012-01-15 14:55Torr SamahoFixed in Version => 1.0
2012-01-15 14:55Torr SamahoResolutionopen => fixed
2012-01-15 14:55Torr SamahoAssigned To => Torr Samaho
2012-06-09 13:22Torr SamahoCategoryGeneral => Bug
2018-09-30 19:57Blzut3Statusresolved => closed

Notes
(0001766)
unknownna   
2011-05-27 04:06   
'http://www.zdoom.org/Changelog/2030/files [^]'

* Fixed: Using Transfer_Heights with the SECF_UNDERWATER and SECF_FAKEFLOORONLY flags applied the water effect to the ceiling and not just the floor.

(0001792)
Torr Samaho   
2011-06-13 15:27   
I backported the fix. Please test it once I made new binaries.
(0002142)
M0rbid Desire   
2011-08-26 21:26   
Fixed in r3299.

* Fixed: Using Transfer_Heights with the SECF_UNDERWATER and SECF_FAKEFLOORONLY flags applied the water effect to the ceiling and not just the floor.