0001000: Double MOTD appearense
Accidentally found that MOTD of server I just connected to has been displayed twice.
Load attached demo.
No tags attached.
? Zandronum_30.08.2012_16.33.25_doom2.wad_zdoomwarsiv2.5v2.pk3_zdoomwarsiv2.5v2patch.wad_zdoomwarsimapsv1.1b.pk3_zdoomwarsimusicpackv2.pk3.cld (19,131) 2012-08-30 10:57
/tracker/file_download.php?file_id=688&type=bug
Issue History
2012-08-30 10:57ZzZomboNew Issue
2012-08-30 10:57ZzZomboFile Added: Zandronum_30.08.2012_16.33.25_doom2.wad_zdoomwarsiv2.5v2.pk3_zdoomwarsiv2.5v2patch.wad_zdoomwarsimapsv1.1b.pk3_zdoomwarsimusicpackv2.pk3.cld
2012-09-01 14:21Torr SamahoNote Added: 0004550
2012-09-01 14:37Torr SamahoStatusnew => feedback
2012-09-02 02:27ZzZomboNote Added: 0004562
2012-09-02 02:27ZzZomboStatusfeedback => new
2012-09-02 14:55Torr SamahoNote Added: 0004570
2012-09-02 14:55Torr SamahoStatusnew => resolved
2012-09-02 14:55Torr SamahoResolutionopen => unable to reproduce
2012-09-02 14:55Torr SamahoAssigned To => Torr Samaho
2012-09-04 18:33ZzZomboNote Added: 0004591
2012-09-04 18:33ZzZomboStatusresolved => feedback
2012-09-04 18:33ZzZomboResolutionunable to reproduce => reopened
2012-11-06 16:18ZzZomboNote Edited: 0004591bug_revision_view_page.php?bugnote_id=4591#r2921
2012-11-06 16:19ZzZomboNote Edited: 0004591bug_revision_view_page.php?bugnote_id=4591#r2922
2012-11-30 06:31ZzZomboNote Added: 0005445
2012-11-30 06:31ZzZomboStatusfeedback => assigned

Notes
(0004550)
Torr Samaho   
2012-09-01 14:21   
Seems to work fine on my local server. Can you reproduce this at will and with any server? Or are only special servers affected?
(0004562)
ZzZombo   
2012-09-02 02:27   
Seems I can't reproduced this bug anymore.
(0004570)
Torr Samaho   
2012-09-02 14:55   
Then let's assume that this was a one time problem. If it happens again, please reopen this ticket.
(0004591)
ZzZombo   
2012-09-04 18:33   
(edited on: 2012-11-06 16:19)
It appears that if your client requests snapshots on high ping machine then the server responds to all of requests and visually it's noticeable by double and even triple MOTDs in the console.

(0005445)
ZzZombo   
2012-11-30 06:31   
There was a strange server a day ago which I couldn't connect to successfully (it seems to be down right now). I have being authenticating level for 4 times, when receiving snapshots for the same 4 times and after that I've got 4 BSP tree building processes that ended in Client_CheckForMissingPackets error. I've tried to reconnect to this server about 7 times with the same results. Possibly you should instruct both the server and the client to ignore commands that were successfully executed in before to avoid such situations.